Montcasyer logo MONTCASYER

Products · Cleanroom Entry Systems

Cleanroom Entry Systems

Air shower and mist shower systems for controlled personnel and material entry and exit into pharmaceutical, biotech and cleanroom environments.

Cleanroom entry system for controlled environments

Entry systems for controlled cleanroom access.

Montcasyer designs and manufactures cleanroom entry and exit systems for facilities where personnel, materials or equipment must pass through a controlled transition before entering classified areas.

Systems can be configured as air showers or mist showers depending on the application, contamination control strategy, installation layout and operating procedure.

01

Controlled entry

Systems support cleanroom access protocols by reducing loose particles or surface contamination before entry into controlled environments.

02

Facility integration

Equipment can be adapted to room layout, door configuration, interlocks, airflow direction, utilities and cleanroom classification requirements.

Air Shower

Air showers are designed for controlled personnel or material entry, using high-velocity filtered air to remove loose particles from external surfaces before entering cleanroom areas.

Air shower for cleanroom entry

Particle reduction

Filtered air jets are directed across the user or material surface to help remove particles before entry into classified or controlled areas.

Access control

Door interlocks, cycle timing and airflow configuration can be adapted to the facility procedure and cleanroom access strategy.

Typical configuration

  • Personnel or material entry
  • HEPA-filtered air supply
  • High-velocity air nozzles
  • Door interlock system
  • Cycle timer and control panel
  • Custom dimensions and finishes

Mist Shower

Mist showers are used where controlled surface wetting or fine mist application is required as part of an entry, exit or decontamination procedure.

Mist shower for controlled cleanroom access

Surface treatment

Fine mist distribution can support defined procedures for personnel, equipment or material movement between controlled areas.

Process adaptation

Mist generation, drainage, door sequence, cycle timing and control logic are defined according to the operating procedure and facility layout.

Typical configuration

  • Controlled mist application
  • Personnel, material or equipment entry
  • Integrated nozzles and drainage
  • Door interlock sequence
  • Cycle control and safety logic
  • Project-specific chamber design

Typical configuration parameters

Equipment type Air shower and mist shower systems
Application Personnel, material or equipment entry into controlled areas
Execution Standalone chamber or integrated cleanroom entry system
Construction Stainless steel or cleanroom-compatible materials
Access Single or double-door configurations with interlocks
Control Cycle timer, operator interface and project-specific logic
Integration Cleanroom envelope, HVAC, drainage or utility connections
Documentation Drawings, manuals and technical files according to scope

Technical documentation for cleanroom entry equipment.

Cleanroom entry systems can be supplied with project-specific documentation supporting installation, inspection, operation and maintenance activities.

  • Technical drawings
  • Material certificates
  • Installation details
  • Operating and maintenance manuals
  • Electrical or control documentation
  • FAT and SAT support

Discuss a cleanroom entry requirement.

For air shower, mist shower or project-specific cleanroom entry requirements, contact Montcasyer’s engineering team.